4–8 wks lead time
🇳🇬Nigeria·Type B · 12 unitsDelivered🇰🇿Kazakhstan·MICU · 6 unitsIn Transit🇸🇦Saudi Arabia·Type C · 20 unitsDelivered🇬🇭Ghana·4×4 Off-Road · 8 unitsIn Transit🇺🇿Uzbekistan·Type B · 15 unitsDelivered🇰🇪Kenya·Hiace BLS · 10 unitsProduction🇦🇿Azerbaijan·Sprinter MICU · 4 unitsIn Transit🇪🇹Ethiopia·4×4 · 6 unitsDelivered🇲🇦Morocco·Type B · 8 unitsDelivered🇳🇬Nigeria·Type B · 12 unitsDelivered🇰🇿Kazakhstan·MICU · 6 unitsIn Transit🇸🇦Saudi Arabia·Type C · 20 unitsDelivered🇬🇭Ghana·4×4 Off-Road · 8 unitsIn Transit🇺🇿Uzbekistan·Type B · 15 unitsDelivered🇰🇪Kenya·Hiace BLS · 10 unitsProduction🇦🇿Azerbaijan·Sprinter MICU · 4 unitsIn Transit🇪🇹Ethiopia·4×4 · 6 unitsDelivered🇲🇦Morocco·Type B · 8 unitsDelivered
← All Mobile Health Vehicles
Mobile Laboratory & Blood Services — image 1 of 9
1 / 9
Laboratory & Blood Services

Mobile Laboratory & Blood Services

Mobile medical laboratory and blood service vehicles — on-site sample collection, processing, basic analysis, and blood donation capability for disease surveillance, outbreak response, and humanitarian health programs.

Mobile laboratory and blood service configurations cover point-of-care diagnostic vehicles for disease surveillance and rapid outbreak response, mobile blood collection units for national blood bank campaigns, and combined lab-blood service platforms for humanitarian and military medical programs. Each vehicle is specified to biosafety requirements, cold chain provisions, generator independence, and clinical workflow — allowing full sample collection, processing, and basic reporting without a fixed laboratory facility.

Platform
Van / Box Body Platform
Vehicle Type
Mobile Laboratory & Blood Collection Vehicle
Category
Laboratory & Blood Services

Clinical & Operational Scope

Mobile Laboratory & Blood Services — Configuration Scope

  • On-site sample collection, processing, and point-of-care analysis — blood, urine, swab confirmed by clinical program
  • Blood donation collection — donor screening, phlebotomy, and cold chain management for blood bank programs
  • Biosafety provisions — cabinet class and extract ventilation confirmed by regulatory and project requirements
  • Cold chain management — refrigerator and freezer for sample and blood product preservation

Key Configuration Features

  • Laboratory workbench and sample processing zone with biosafety provisions
  • Cold storage — refrigerator and freezer for sample and blood product preservation
  • Point-of-care analyser and rapid diagnostic test provisions
  • Blood donation stations — reclining donor chairs and collection system
  • Biohazard and sharps waste management system
  • Generator for independent field deployment

Typical Use Cases

  • Communicable disease surveillance and outbreak rapid response
  • National blood service donor campaign and mobile collection programs
  • Government and ministry public health laboratory outreach
  • NGO and humanitarian rapid health assessment programs
  • Military and civil defense field laboratory deployment

Equipment & Interior Scope

  • Clinical laboratory workbench — sample reception and processing
  • Biosafety cabinet provisions — class confirmed by regulatory scope
  • Blood product refrigerator and freezer for cold chain management
  • Point-of-care haematology, biochemistry, and rapid test provisions
  • Reclining phlebotomy donor chairs for blood collection programs

Configuration Reference

Vehicle Compartment & Equipment Scope

Reference data for procurement planning. Final dimensions, equipment layout, and clinical configuration are confirmed during Ramsbulance project specification according to operator requirements and destination-market standards.

Compartment Reference

Sample Processing Zone
Clinical laboratory workbench with power, water, and ventilation
Biosafety Cabinet
Class II provisions — specification confirmed by regulatory requirements
Cold Storage
Refrigerator (+2°C to +8°C) and freezer (−20°C) for samples and blood products
Donor Stations
Reclining phlebotomy chairs — 2–4 stations for blood collection programs
Waste Management
Biohazard and sharps disposal — regulated waste containment
Power System
Shore power + generator with ATS — cold storage and equipment priority

Standard Scope

  • Laboratory workbench with power and ventilation
  • Sample reception and cold storage provisions
  • Biohazard and sharps waste disposal system
  • Clean water supply and drainage
  • Shore power inlet and generator with ATS
  • Antibacterial surface treatment throughout
  • LED clinical working lighting

Optional Additions

  • Class II biosafety cabinet — confirmed by project scope
  • Point-of-care analyser — haematology, biochemistry, or PCR provisions
  • Blood donor stations and collection system
  • Laboratory information system and result reporting connectivity
  • GPS tracking and fleet management integration

Procurement Reference

Technical Specification Snapshot

Exact dimensions, payload, electrical architecture, and medical equipment scope are confirmed during project specification. Ramsbulance can provide technical drawings, specification files, and certification documents for qualified procurement review.

Technical Reference

Base Platform
Van or box body — confirmed by laboratory equipment and cold storage requirements
Clinical Configuration
Mobile laboratory / blood collection — processing zone, biosafety, cold storage, and donor stations
Cold Storage
Refrigerator (+2°C to +8°C) and freezer (−20°C) — cold chain confirmed by program scope
Power System
Shore power + generator with ATS — cold storage and equipment priority circuit
Certifications
ISO 9001, ISO 13485, CE — biosafety certification per destination country scope
Documentation
Technical specification and equipment list available for procurement review

Procurement Notes

Order Size
Single units and fleet volumes — blood service fleet programs and outbreak response units available
Configuration Type
Laboratory-only, blood service-only, or combined platforms confirmed at project scope stage
Cold Chain Spec
Refrigerator and freezer specification confirmed by sample type, transport duration, and program requirements
Buyer Information Needed
Clinical program type, cold chain requirements, analyser preferences, donor station count, and fleet size

Export Documentation Package

Standard documents provided with every Ramsbulance delivery for international procurement, customs clearance, and institutional documentation.

  • Vehicle build specification document
  • Electrical system diagram and schematic
  • Equipment identification list with serial numbers
  • ISO 9001 quality management certificate
  • ISO 13485 medical device quality management certificate
  • CE declarations of conformity for applicable equipment
  • Country-of-origin documentation for export customs
  • Delivery and handover documentation package

Request the technical specification sheet for this mobile health vehicle — available for qualified institutional buyers, government ministries, NGO procurement teams, and tender evaluation offices.

Message us on WhatsApp

Typically reviewed within 24 hours.

Ask anything