Délai 4–8 semaines
🇳🇬Nigeria·Type B · 12 unitsLivré🇰🇿Kazakhstan·MICU · 6 unitsEn transit🇸🇦Saudi Arabia·Type C · 20 unitsLivré🇬🇭Ghana·4×4 Off-Road · 8 unitsEn transit🇺🇿Uzbekistan·Type B · 15 unitsLivré🇰🇪Kenya·Hiace BLS · 10 unitsEn production🇦🇿Azerbaijan·Sprinter MICU · 4 unitsEn transit🇪🇹Ethiopia·4×4 · 6 unitsLivré🇲🇦Morocco·Type B · 8 unitsLivré🇳🇬Nigeria·Type B · 12 unitsLivré🇰🇿Kazakhstan·MICU · 6 unitsEn transit🇸🇦Saudi Arabia·Type C · 20 unitsLivré🇬🇭Ghana·4×4 Off-Road · 8 unitsEn transit🇺🇿Uzbekistan·Type B · 15 unitsLivré🇰🇪Kenya·Hiace BLS · 10 unitsEn production🇦🇿Azerbaijan·Sprinter MICU · 4 unitsEn transit🇪🇹Ethiopia·4×4 · 6 unitsLivré🇲🇦Morocco·Type B · 8 unitsLivré
← Tous les modèles
Ambulance de soins intensifs mobiles (MICU) — image 1 of 5
1 / 5
Ambulance de soins intensifs

Ambulance de soins intensifs mobiles (MICU)

Ambulance de réanimation Type C configurée pour la surveillance continue du patient critique, l'intégration d'équipements de réanimation avancés et un flux de travail clinique continu pendant le transport.

Mobile intensive care unit ambulance configurations can be planned around critical care equipment, patient monitoring, multi-channel infusion capability, ventilation, and the electrical architecture needed to support high-load clinical workflows during patient transfer. The MICU layout provides attendant workspace, standing headroom, and structured clinical access to the patient zone.

Plateforme
Mercedes-Benz Sprinter / High-Roof Van
Type d'ambulance
Type C / Unité mobile de soins intensifs (MICU)
Catégorie
Ambulance de soins intensifs

Certification EN 1789

Unité mobile de soins intensifs Type C — Configuration réanimation avancée

  • EN 1789 Type C: mobile intensive care unit configured for critical care patient monitoring, treatment, and transport
  • Full standing height patient compartment with structured bilateral attendant clinical workspace
  • Advanced equipment integration including ventilator, cardiac monitor, multi-channel infusion, and full oxygen supply
  • Type C configuration and equipment scope confirmed at project specification stage according to clinical requirements

Caractéristiques de configuration clés

  • Aménagement intérieur Type C / MICU pour transport en réanimation avancée
  • Compartiment patient en hauteur debout complète pour le flux de travail du soignant
  • Intégration d'équipements de monitoring et de réanimation avancés
  • Emplacements pour pompes à perfusion multivoies et ventilateur de transport
  • Architecture électrique double haute capacité — 12 V et 220 V
  • Espace de travail clinique structuré avec accès rapide à l'équipement

Cas d'utilisation typiques

  • Transfert inter-établissements de patients en soins intensifs
  • Transport de patients post-opératoires entre hôpitaux
  • Programmes de transport en réanimation néonatale et pédiatrique
  • Programmes de flotte soins critiques pour hôpitaux publics et privés
  • Marchés publics institutionnels internationaux de réanimation avancée

Équipement et portée intérieure

  • Système de fixation moniteur cardiaque / défibrillateur
  • Rail pour pompes à perfusion et seringues
  • Support ventilateur de transport au chevet du patient
  • Conduite d'oxygène complète avec sorties multiples en zone patient
  • Pied à perfusion IV et système de suspension médicament sur rail plafond

Référence de configuration

Compartiment patient et portée équipement

Données de référence pour la planification des achats. Les dimensions finales, la disposition des équipements et la configuration clinique sont confirmées lors de la spécification du projet Ramsbulance selon les exigences de l'opérateur et les standards du marché de destination.

Référence du compartiment patient

Working Height
Full standing height — high-roof configuration ≥ 1,800 mm reference for Type C clinical workflow
Patient Zone
Structured critical care layout with stretcher, bilateral attendant access, and equipment rail system
Stretcher Position
EN 1789-compliant main stretcher with cot-fastener system and bilateral side attendant access
Attendant Positions
2 attendant positions — clinical workflow access from both sides of stretcher
Equipment Rails
IV rail system and equipment mounting rail — continuous from head to foot zone
Electrical System
High-capacity 12V / 220V dual power — inverter, shore power inlet, priority medical outlet circuit
Oxygen System
Multi-outlet oxygen pipeline — patient zone, crew zone, and ventilator supply points
Infusion Mounts
Minimum 2-channel infusion pump positions; syringe pump rail space
Ventilator Position
Transport ventilator bracket at head zone; airway equipment rapid-access position
Storage
Lockable medication cabinet, ALS equipment drawers, IV consumables — quick-release access

Portée équipement standard

  • EN 1789 Type C main stretcher with cot-fastener and bilateral side access
  • Dual power architecture — 12V vehicle / 220V inverter and shore power inlet
  • Multi-outlet oxygen pipeline — patient and crew zone supply
  • Equipment rail system — IV, infusion pump, and monitoring mount
  • Transport ventilator bracket and airway equipment position
  • Cardiac monitor / defibrillator mounting and cable management
  • Lockable medication and controlled drug cabinet
  • LED clinical lighting — white and red mode with task lighting over patient
  • Full-height antibacterial interior surface treatment
  • ALS consumables storage with rapid-access draw system

Ajouts optionnels

  • Neonatal incubator mounting and transport power provisions
  • CPAP / BiPAP provisions and respiratory therapy equipment mounting
  • Patient compartment HVAC climate control for temperature-sensitive transport
  • CO₂ / capnography module integration
  • Patient data transmission and remote monitoring system
  • Destination-market specific clinical equipment certification on request
  • Livery, branding, and institutional fleet graphics package

Référence d'approvisionnement

Aperçu des spécifications techniques

Les dimensions exactes, la charge utile, l'architecture électrique et la portée des équipements médicaux sont confirmées lors de la spécification du projet. Ramsbulance peut fournir des plans techniques, des fichiers de spécifications et des documents de certification pour la revue d'approvisionnement qualifiée.

Référence technique

Plateforme de base
Mercedes-Benz Sprinter or equivalent high-roof van platform
Ambulance Configuration
Type C Mobile Intensive Care Unit — full ALS critical care layout
Compartiment patient
Full standing height with bilateral attendant access and equipment rail system
Système électrique
High-capacity dual ambulance power — 12V / 220V with medical priority circuit
Système d'oxygène
Multi-outlet pipeline with ventilator, patient, and crew supply points
Ensemble de documentation
Type C technical specification files and certification documentation available on request

Notes d'approvisionnement

Taille de commande
Confirmée lors de la cotation selon le modèle, la configuration et le marché de destination.
Délai de production
La production typique est de 8 à 16 semaines à partir de la spécification confirmée, selon la configuration et la quantité. Confirmé après la spécification technique, le périmètre des équipements et la revue de documentation.
Fiche technique
Fiche technique et plans disponibles pour les demandes d'achat qualifiées.
Informations acheteur requises
Pays, quantité, utilisation prévue, plate-forme véhicule et niveau d'équipement.

Référence du châssis de base

Les données du châssis OEM sont présentées comme référence pour la revue d'approvisionnement. Les dimensions finales de l'ambulance, le poids, la charge utile, l'architecture électrique et la portée équipement sont confirmés lors de la spécification du projet Ramsbulance.

Base Chassis
Mercedes-Benz Sprinter high-roof cargo van — Type C MICU conversion platform
Working Height Reference
≥ 1,800 mm patient compartment height — standing height throughout the clinical workspace
Patient Zone Length Reference
≥ 3,000 mm patient compartment zone with full bilateral attendant access
Power Architecture Reference
12V vehicle + 220V inverter (3,000 W+ reference) + shore power inlet — confirmed by equipment load calculation
Oxygen Architecture Reference
H-cylinder or E-cylinder system with pipeline and 4+ outlet points — confirmed by equipment scope
Conversion Note
Type C MICU configuration — final clinical layout, electrical load, and equipment integration confirmed at project specification stage

Les données du châssis de base sont fournies à titre de référence OEM. La variante réelle, l'empattement, les dimensions, la charge utile, le poids des équipements et les spécifications du marché de destination sont confirmés lors de la revue du projet Ramsbulance. Les valeurs finales de conversion en ambulance dépendent du châssis sélectionné, du périmètre des équipements médicaux, de l'agencement intérieur et de la documentation de certification.

Package de documentation d'exportation

Documentation standard fournie avec chaque livraison Ramsbulance pour les achats internationaux, le dédouanement et la tenue de dossiers institutionnels.

  • Certificat de conformité du fabricant du véhicule
  • Documentation de certification EN 1789
  • Certificats qualité ISO 9001 et ISO 13485
  • Plans techniques et spécification de configuration confirmée
  • Liste d'équipements et confirmation du périmètre de conversion
  • Documentation opérateur et d'entretien
  • Documentation de conformité douanière et à l'exportation
  • Facture commerciale, liste de colisage et certificat d'origine (sur demande)

Demandez la fiche technique, les plans et les documents de certification pour ce modèle lors de la revue d'achat.

Écrivez-nous sur WhatsApp

Réponse généralement sous 24 heures.

Posez votre question